Whether you're looking to upgrade or in need of a replacement, we sell and recommend Bradford White water heaters and Delta faucets.
Farmers Branch, Texas
Imperial Plumbing serves all of the city of Farmers Branch, Texas including the following zip codes: 75234, 75244.
Water Heater Installation Requirements Info:
- Phone Number for Building Inspections Division: 972.919.2549 
- Water Heaters above ground or floor - When the attic, roof, mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. - Exception: A max 10 gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and a water heater is installed is not more than ten (10) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. - Whenever the mezzanine or platform is not adequately lighted or access to a receptacle outlet is not obtainable from the main level, lighting and a receptacle outlet shall be provided in accordance with Section 502.1. 
Farmers Branch Plumbing Code Tips:
- Uses the 2012 edition of the International Plumbing Code. 
- Link to information about the plumbing code: http://www.farmersbranch.info/DocumentCenter/View/1419 
- Requirements for Discharge Piping - The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 
- Not be directly connected to the drainage system. 
- Discharge through an air gap. 
- Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 
- Serve a single relief device and shall not connect to piping serving any other relief device or equipment. - Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufacture's installation instructions and installed according to those instructions. 
- Discharge to an indirect waste receptor or to the outdoors. 
- Discharge in a manner that does not cause personal injury or structural damage. 
- Discharge to a termination point that is readily observable by the building occupants. 
- Not be trapped. 
- Be installed so as to flow by gravity. 
- Not terminate less than 6 inches or more than 24 inches (152 mm) above grade no more than 6 inches above the waste receptor. 
- Not have a threaded connection at the end of such piping. 
- Location of shutoff valves - Shutoff valves shall be installed in the following locations: 
- On the fixture supply to each plumbing fixture other than bathtubs and showers. 
- On the water supply pipe to each sillcock when subject to freezing. 
- On the water supply pipe to each appliance or mechanical equipment. 
Services We Provide in Farmers Branch, Texas
- Preventative Maintenance Checkups 
- Water Heater Replacement 
- Slab Leak Repair 
- Plumbing Remodel 
- Faucet Repair & Replacement 
- Toilet Repair & Replacement 
- Shower and Bathtub Repair & Replacement 
- Garbage Disposal Replacement 
- Natural Gas Leak Repair 
- Emergency Service 8am-8pm Daily 
 
                         Cash, and Check
 Cash, and Check
   
            
              
            
            
          
               
            
              
            
            
          
              